00695
R/U Quantity/Timing Qualifier
2000-10-28
Components: <quantity (CQ)> ^ <interval (CM)> ^ <duration (CM)> ^ <start date/time (TS)> ^ <end date/time (TS)> ^ <priority (ST)> ^ <condition (ID)> ^ <text (TX)> ^ <conjunction (ID)> ^ <order sequencing (CM)> ^ <occurrence duration (CE)> ^ <total occurrences (NM)>
Definition: This field allows an interval definition to be used for specifying multiple responses to a query. With the addition of this filter, new query specifications should no longer use URS-2-R/U when data start date/time and URS-3-R/U when data end date/time in future implementations.
Length≤60
12 components
| 1 | O | - | quantity | |
| 2 | O | - | interval | |
| 3 | O | - | duration | |
| 4 | O | - | start date/time | |
| 5 | O | - | end date/time | |
| 6 | O | - | priority | |
| 7 | O | - | condition | |
| 8 | O | - | text (TX) | |
| 9 | O | - | conjunction component | |
| 10 | O | - | order sequencing | |
| 11 | O | - | occurrence duration | |
| 12 | O | - | total occurences |