00695

R/U Quantity/Timing Qualifier

2007-05-08
Definition: This field allows an interval definition to be used for specifying multiple responses to a query. With the addition of this filter, new query specifications should no longer use URS-2-R/U when data start date/time and URS-3-R/U when data end date/time in future implementations.
Note: This field is of data type TQ, which has been deprecated in Version 2.5. Please refer to Section 2.A.81 of Chapter 2, “Data Types,” for information on implementing the quantity component (component 1).
Length≤60
12 components
1O-Quantity
2O-Interval
3O-Duration
4O-Start Date/Time
5O-End Date/Time
6O-Priority
7O-Condition
8O-Text
9OConjunction
10O-Order Sequencing
11O-Occurrence Duration
12O-Total Occurrences