ADT_A39
ADT/ACK - Merge Person - Patient ID (Event A39)
7 segments · 4 events
Event A39 has been retained for backward compatibility only. From V2.3.1 onwards, event A40 (merge patient - patient identifier list) should be used instead. A merge has been done at the patient identifier level. That is, two PID-2 - Patient ID identifiers have been merged into one.
An A39 event is used to signal a merge of records for a person that was incorrectly filed under two different PID-2 - Patient IDs. The _incorrect source patient ID_ identified in the MRG segment (MRG-4 - Prior Patient ID) is to be merged with the required _correct target patient ID_ identified in the PID segment (PID-2 - Patient ID). The _incorrect source patient ID_ would then logically never be referenced in future transactions. It is noted that some systems may still physically keep this _incorrect identifier_ for audit trail purposes or other reasons associated with database index implementation requirements.
Message Structure
7 segments
R RequiredO Optional Choice
MSH
R1SFT
O*EVN
R1PATIENT
R*PID
R1PD1
O1MRG
R1PV1
O14 events