00245

Specimen Action Code *

2007-10-26
Definition: This field identifies the action to be taken with respect to the specimens that accompany or precede this order. The purpose of this field is to further qualify (when appropriate) the general action indicated by the order control code contained in the accompanying ORC segment. For example, when a new order (ORC - "NW") is sent to the lab, this field would be used to tell the lab whether or not to collect the specimen ("L" or "O"). Refer to HL7 Table 0065 - Specimen Action Code for valid values.
Length≤1
7 values
AAdd ordered tests to the existing specimen
GGenerated order; reflex order
LLab to obtain specimen from patient
OSpecimen obtained by service other than Lab
PPending specimen; Order sent prior to delivery
RRevised order
SSchedule the tests specified below
IDCoded Value for HL7 Defined TablesPrimitive