00685
Primary Key Value - PRA
2007-10-26
Definition: For MFN Master File Notification, this field is required and must match MFE-4-primary key value to identify which entry is being referenced. For all other messages, this field should not be used.
Length≤250
9999no table for CE
9 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | O | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | O | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text |