ADT_A18

ADT/ACK - Merge Patient Information (Event A18)

7 segments · 1 events

Event A18 has been retained for backward compatibility only in version 2.3.1. Refer to sections 3.3.40, 3.3.41 and 3.3.42 instead. The A18 event was used to merge current and previous patient identification numbers: PID-3 - Patient Identifier List, PID-2 - Patient ID, PID-4 - Alternate Patient ID-PID, and PID-18 - Patient Account Number. This procedure is required, for example, when a previous patient is registered under a new patient identification number because of an error, or because there was insufficient time to determine the actual patient identification number. The merge event occurs when a decision is made to combine the information under either the new or the old identifier(s). The PID segment contains the surviving patient ID information. The MRG segment contains the non-surviving information.

From V2.3.1 onwards events A40 (merge patient-patient identifier list), A41 (merge account-patient account number), and A42 (merge visit-visit number) should be utilized in place of the A18 event.

Message Structure

7 segments
R RequiredO Optional Choice
MSH
R1
SFT
O*
EVN
R1
PID
R1
PD1
O1
MRG
R1
PV1
R1
Used by Events:A18ADT/ACK - Merge patient information (for backward compatibility only)