Annotations
Errata, corrections, and ballot comments for HL7 v2.7
open
QRD, QRF, URD, URS
Segments have been deleted with their definitions, but not from the messages
Resolutionadd as placeholder
open
Z-events
quite a lot of Z-events are specified
Resolutionthey are added to the events table, this includes also the message structures
open
RXE-2, STF-2, STF-19, OM1-44, LCH-5
two or more tables are assigned to the fields, but not to the components
Resolutionthey are not added to the db
open
old and events for future use
those events are not listed in table 0003
Resolutionthey are added to table 0003the same applies to the message types and structures
open
MSG
length is defined as "3,7"
Resolutionthis can only be stored as min=3 and max=7
EHC_E10, EHC_20, EHC_E24
adjusted message structure definition
Resolutionconverted "[" + "{" into "[{"
MDM_T02
segment group without a name
Resolutioncopied "OBSERVATION" from previous version
About Annotations
Annotations include errata, corrections, and ballot comments that were published after the initial release of the HL7 v2.7 specification. These provide important clarifications and fixes to the standard.