01295
Location Characteristic ID
2014-11-02
Definition: This field contains an identifier code to show WHICH characteristic is being communicated with this segment. Refer to User-defined Table 0324 - Location Characteristic ID in Chapter 2C, Code Tables, for suggested values.
LengthNot specified
12 values
GEN | Gender of patient(s) |
IMP | Implant: can be used for radiation implant patients |
INF | Infectious disease: this location can be used for isolation |
LCR | Level of care |
LIC | Licensed |
OVR | Overflow |
PRL | Privacy level: indicating the level of private versus non-private room |
SET | Bed is set up |
SHA | Shadow: a temporary holding location that does not physically exist |
SMK | Smoking |
STF | Bed is staffed |
TEA | Teaching location |
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |