00942
Modality of Imaging Measurement
2014-11-02
Definition: This optional attribute describes the modality used to acquire the observation data, e.g., radiograph, ultrasound, CT scan, MR, etc. This attribute is especially important for imaging studies. Refer to External Table 0910 - Acquisition Modality in Chapter 2C, Code Tables, for the defined value set, which may be repalce or extended with local codes. If the DICOM codes are used, the coding system ID is DCM.
Note: The use of User-defined Table 0259 - Modality for this field is deprecated and retained for backward compatibility as of v 2.7.
LengthNot specified
0910Acquisition Modality
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |