OM4

Observations that Require Specimens

The Technical Steward for the OM4 segment is Orders and Observations.

This segment applies to observations/batteries that require a specimen for their performance. When an observation or battery requires multiple specimens for their performance (e.g., creatinine clearance requires a 24-hour urine specimen and a serum specimen), multiple segments may be included, one for each specimen type.

18
C.LenElementv2.8
1--NMO1-00586OM4-1Sequence Number - Test/Observation Master FileConf Length
21-IDO1017000642OM4-2Derived Specimen
31..60-TXO*-00643OM4-3Container DescriptionConf Length
4--NMO*-00644OM4-4Container VolumeConf Length
5--CWEO*999900645OM4-5Container Units
6--CWEO1999900646OM4-6Specimen
7--CWEO1037100647OM4-7Additive
8--TXO1-00648OM4-8Preparation
9--TXO1-00649OM4-9Special Handling Requirements
10--CQO1-00650OM4-10Normal Collection Volume
11--CQO1-00651OM4-11Minimum Collection Volume
12--TXO1-00652OM4-12Specimen Requirements
131-IDO*002700653OM4-13Specimen Priorities
14--CQO1-00654OM4-14Specimen Retention Time
15--CWEO*037601908OM4-15Specimen Handling Code
16--IDO1092003311OM4-16Specimen Preference
17--NMO1-03312OM4-17Preferred Specimen/Attribture Sequence ID
18--CWEO*-01539OM4-18Taxonomic Classification Code
3