SCP

Sterilizer Configuration (Anti-Microbial Devices)

The sterilization configuration segment contains information specific to configuration of a sterilizer or washer for processing sterilization or decontamination loads.
8
C.LenElementv2.8
1--NMO1-02087SCP-1Number Of Decontamination/Sterilization DevicesConf Length
2--CWEO1065102088SCP-2Labor Calculation Type
3--CWEO1065302089SCP-3Date Format
4--EIO1-02090SCP-4Device Number
5--STO1-02279SCP-5Device NameConf Length
6--STO1-02091SCP-6Device Model NameConf Length
7--CWEO1065702092SCP-7Device Type
8--CWEO1065902093SCP-8Lot Control
Used In Message Structures