00231
Entering Organization
2015-07-13
Definition: This field is retained for backward compatibility only as of v 2.7. The reader is referred to the PRT segment described in Chapter 7.
This field identifies the organization that the enterer belonged to at the time he/she enters/maintains the order, such as medical group or department. The person who entered the request is defined in ORC-10-entered by.
LengthNot specified
9999no table for CE
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |