00301

Requested Dispense Code

2014-03-17
Definition: This field indicates what is to be/was dispensed; it is analogous to OBR-4-universal service ID in function. It may be present in the order or not, depending on the application. If not present, and values are given for RXO-11-requested dispense amount and RXO-12-requested dispense units, the RXO-1-requested give code is assumed. If the requested dispense code does not include the dosage form, then RXO-5-requested dosage form is required
Note on request-to-dispense fields:
LengthNot specified
9999no table for CE
22 components
1O-Identifier
2O-Text
3CName of Coding System
4O-Alternate Identifier
5O-Alternate Text
6CName of Alternate Coding System
7C-Coding System Version ID
8O-Alternate Coding System Version ID
9O-Original Text
10O-Second Alternate Identifier
11O-Second Alternate Text
12CName of Second Alternate Coding System
13O-Second Alternate Coding System Version ID
14C-Coding System OID
15O-Value Set OID
16C-Value Set Version ID
17C-Alternate Coding System OID
18O-Alternate Value Set OID
19C-Alternate Value Set Version ID
20C-Second Alternate Coding System OID
21O-Second Alternate Value Set OID
22C-Second Alternate Value Set Version ID