8.5.2 MFE - Master File Entry Segment:
The Technical Steward for the MFE segment is Infrastructure and Messaging.
Fields
R
Required
O
Optional
C
Conditional
W
Withdrawn
|
#
Date/Time
*
Backward compat.
+
Filler
7
#
Len
C.Len
DT
Opt
RP/#
TBL#
Item#
Element
Element Name
1
3
-
ID
R
1
0180
00664
MFE-1
Record-Level Event Code
2
-
20
=
ST
C
1
-
00665
MFE-2
MFN Control ID
3
-
-
DTM
O
1
-
00662
MFE-3
Effective Date/Time
4
-
-
varies
R
*
9999
00667
MFE-4
Primary Key Value - MFE
5
2..3
-
ID
R
*
0355
01319
MFE-5
Primary Key Value Type
6
-
-
DTM
O
1
-
00661
MFE-6
Entered Date/Time
7
-
-
XCN
O
1
-
00224
MFE-7
Entered By
Used In Message Structures