0914

Root Cause

Introduced in v2.8· user· Steward: OO· example· 5 values

THO:RootCausev2.0.0

Code system of concepts specifying the root cause. Used in HL7 Version 2.x messaging in the OBX segment.

No description available in the specification.

OID & Vocabulary Information

THO Canonical URL (v2.0.0)
http://terminology.hl7.org/CodeSystem/v2-0914
Table OID
2.16.840.1.113883.12.914
Codesystem OID (v1)
2.16.840.1.113883.18.421
Value Set OID
2.16.840.1.113883.21.439
Binding
example
Expansion
All codes from codesystem
Where Used
OBX-27
UTG Code Table
new cs
Used In Data Elements
5
AP
Analysis Process(Enter (AP) when ANALYSIS PROCESS is the reason due to:<p>• Product or supply failure (reagents, calibrators, QC material)<p>• Equipment or instrumentation failure)
Usage: Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure
THO: Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure
THO Usage: Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure
IM
Information Management(Enter (IM) when INFORMATION MANAGEMENT is the reason due to:<p>• Database or Programming issues<p>• Overriding of test results<p>• Inaccurate calculations<p>• Inaccurate flagging, reference ranges, units of measure<p>• Incomplete/inaccurate tran)
Usage: Enter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other
THO: Enter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other
THO Usage: Enter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other
L
Laboratory(Enter (L) when LABORATORY is the reason due to:<p>• Data Entry error<p>• Testing/Technical error<p>• Repeat testing causing change to test result)
Usage: Enter (L) when LABORATORY is the reason due to: • Data Entry error • Testing/Technical error • Repeat testing causing change to test result
THO Usage: Enter (L) when LABORATORY is the reason due to: • Data Entry error • Testing/Technical error • Repeat testing causing change to test result
NA
Not Applicable(Enter (NA) when NOT-APPLICABLE is the reason due to:<p>• If no revisions performed or<p>• unable to determine reason for revision<p>Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a cor)
Usage: Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)
THO: Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)
THO Usage: Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision)
PD
Placer Data(Enter (PD) when new or changed PLACER DATA information is the reason due to:<p>• Changed patient demographics or<p>• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous)
Usage: Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)
THO: Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)
THO Usage: Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...)
5 codes