0914
Root Cause
Introduced in v2.8· user· Steward: OO· example· 5 values
THO:RootCausev2.0.0
Code system of concepts specifying the root cause. Used in HL7 Version 2.x messaging in the OBX segment.
No description available in the specification.
OID & Vocabulary Information
- THO Canonical URL (v2.0.0)
- http://terminology.hl7.org/CodeSystem/v2-0914
- Table OID
- 2.16.840.1.113883.12.914
- Codesystem OID (v1)
- 2.16.840.1.113883.18.421
- Value Set OID
- 2.16.840.1.113883.21.439
- Binding
- example
- Expansion
- All codes from codesystem
- Where Used
- OBX-27
- UTG Code Table
- new cs
Used In Data Elements
5
AP | Analysis Process(Enter (AP) when ANALYSIS PROCESS is the reason due to:<p>• Product or supply failure (reagents, calibrators, QC material)<p>• Equipment or instrumentation failure) Usage: Enter (AP) when ANALYSIS PROCESS is the reason due to:
• Product or supply failure (reagents, calibrators, QC material)
• Equipment or instrumentation failure THO: Enter (AP) when ANALYSIS PROCESS is the reason due to:
• Product or supply failure (reagents, calibrators, QC material)
• Equipment or instrumentation failure THO Usage: Enter (AP) when ANALYSIS PROCESS is the reason due to:
• Product or supply failure (reagents, calibrators, QC material)
• Equipment or instrumentation failure |
IM | Information Management(Enter (IM) when INFORMATION MANAGEMENT is the reason due to:<p>• Database or Programming issues<p>• Overriding of test results<p>• Inaccurate calculations<p>• Inaccurate flagging, reference ranges, units of measure<p>• Incomplete/inaccurate tran) Usage: Enter (IM) when INFORMATION MANAGEMENT is the reason due to:
• Database or Programming issues
• Overriding of test results
• Inaccurate calculations
• Inaccurate flagging, reference ranges, units of measure
• Incomplete/inaccurate transmission of test results
• Other THO: Enter (IM) when INFORMATION MANAGEMENT is the reason due to:
• Database or Programming issues
• Overriding of test results
• Inaccurate calculations
• Inaccurate flagging, reference ranges, units of measure
• Incomplete/inaccurate transmission of test results
• Other THO Usage: Enter (IM) when INFORMATION MANAGEMENT is the reason due to:
• Database or Programming issues
• Overriding of test results
• Inaccurate calculations
• Inaccurate flagging, reference ranges, units of measure
• Incomplete/inaccurate transmission of test results
• Other |
L | Laboratory(Enter (L) when LABORATORY is the reason due to:<p>• Data Entry error<p>• Testing/Technical error<p>• Repeat testing causing change to test result) Usage: Enter (L) when LABORATORY is the reason due to:
• Data Entry error
• Testing/Technical error
• Repeat testing causing change to test result THO Usage: Enter (L) when LABORATORY is the reason due to:
• Data Entry error
• Testing/Technical error
• Repeat testing causing change to test result |
NA | Not Applicable(Enter (NA) when NOT-APPLICABLE is the reason due to:<p>• If no revisions performed or<p>• unable to determine reason for revision<p>Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a cor) Usage: Enter (NA) when NOT-APPLICABLE is the reason due to:
• If no revisions performed or
• unable to determine reason for revision
Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision) THO: Enter (NA) when NOT-APPLICABLE is the reason due to:
• If no revisions performed or
• unable to determine reason for revision
Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision) THO Usage: Enter (NA) when NOT-APPLICABLE is the reason due to:
• If no revisions performed or
• unable to determine reason for revision
Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision) |
PD | Placer Data(Enter (PD) when new or changed PLACER DATA information is the reason due to:<p>• Changed patient demographics or<p>• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous) Usage: Enter (PD) when new or changed PLACER DATA information is the reason due to:
• Changed patient demographics or
• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) THO: Enter (PD) when new or changed PLACER DATA information is the reason due to:
• Changed patient demographics or
• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) THO Usage: Enter (PD) when new or changed PLACER DATA information is the reason due to:
• Changed patient demographics or
• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) |
5 codes