ADT_A50

ADT^A50 Acknowledgment Choreography

ADT^A50
A change has been done at the visit identifier level. That is, a PV1-19 - Visit Number has been found to be incorrect and has been changed.

An A50 event is used to signal a change of an incorrectly assigned visit number value. The "incorrect source visit number" value is stored in the MRG segment (MRG-5 - Prior Visit Number) and is to be changed to the "correct target visit number" value stored in the PV1 segment (PV1-19 - Visit Number).

Acknowledgment Rules(10)

ModeMSH-15MSH-16Immediate ACKApplication ACK
Originalblankblank-
^^
EnhancedNENE--
EnhancedAL,SU,ERNE
^^
-
EnhancedNEAL,SU,ER-
^^
EnhancedAL,SU,ERAL,SU,ER
^^
^^
Originalblankblank-
^^
EnhancedNENE--
EnhancedAL,SU,ERNE
^^
-
EnhancedNEAL,SU,ER-
^^
EnhancedAL,SU,ERAL,SU,ER
^^
^^

Legend

blank - Field is empty/not valued
NE - Never (no acknowledgment)
AL - Always
SU - Success only
ER - Error/reject only