00616
Observations Required to Interpret this Observation
2020-01-06
Note: This field is deprecated and retained for backward compatibility as of v 2.8.2. See OMC Segment.
Definition: This field contains the list of variables that the diagnostic service needs to interpret the results of an ordered study. The observations specified here should be sent to the diagnostic service as OBX segments along with the order (OBR) segment. Separate multiple items by repeat delimiters. Refer to Table 0639 - Observations Required to Interpret this Observation in Chapter 2C for valid values.
LengthNot specified
0639Observations Required to Interpret this Observation (OM1-31)
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |