00953

Location Equipment

2020-01-06
Definition: This repeating field indicates what types of equipment are built in. Applies only to room or bed locations. If LOC-3 - Location Type indicates that this is a room, this will be the equipment in the room which can be used by more than one bed. If LOC-3 - Location Type indicates this is a bed, this will be the bedside devices available to this bed. Refer to User-defined Table 0261 - Location Equipment in Chapter 2C, Code Tables, for suggested values.
Length3 (No truncation)
8 values
EEGElectro-Encephalogram
EKGElectro-Cardiogram
INFInfusion pump
IVPIV pump
OXYOxygen
SUCSuction
VENVentilator
VITVital signs monitor
22 components
1O-Identifier
2O-Text
3CName of Coding System
4O-Alternate Identifier
5O-Alternate Text
6CName of Alternate Coding System
7C-Coding System Version ID
8O-Alternate Coding System Version ID
9O-Original Text
10O-Second Alternate Identifier
11O-Second Alternate Text
12CName of Second Alternate Coding System
13O-Second Alternate Coding System Version ID
14C-Coding System OID
15O-Value Set OID
16C-Value Set Version ID
17C-Alternate Coding System OID
18O-Alternate Value Set OID
19C-Alternate Value Set Version ID
20C-Second Alternate Coding System OID
21O-Second Alternate Value Set OID
22C-Second Alternate Value Set Version ID