00953
Location Equipment
2020-01-06
Definition: This repeating field indicates what types of equipment are built in. Applies only to room or bed locations. If LOC-3 - Location Type indicates that this is a room, this will be the equipment in the room which can be used by more than one bed. If LOC-3 - Location Type indicates this is a bed, this will be the bedside devices available to this bed. Refer to User-defined Table 0261 - Location Equipment in Chapter 2C, Code Tables, for suggested values.
Length3 (No truncation)
8 values
EEG | Electro-Encephalogram |
EKG | Electro-Cardiogram |
INF | Infusion pump |
IVP | IV pump |
OXY | Oxygen |
SUC | Suction |
VEN | Ventilator |
VIT | Vital signs monitor |
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |