OMI_O23
OMI – Imaging Order Message (Event O23)
38 segments · 1 events
Figure not available in HL7 v2.9 —
Figure 4-1 – Use of OMI messagech04_01.svg is not published in this version of the specification.This message is used in communication between the information systems involved in the fulfillment of the request directed to the imaging department, such as a Radiology Information System (RIS) and a Picture Archiving and Communication System (PACS). For the purpose of the following discussion these systems will be identified as Imaging Department Information Systems (IDIS). Information contained in the Imaging Procedure Control (IPC) segment allows multiple IDIS to share the context of Imaging Studies (collections of images acquired, processed, stored, and interpreted) in Image Management tasks.
Figure 4-1 – Use of OMI message
Message Structure
38 segments
R RequiredO Optional Choice
MSH
R1ARV
O*SFT
O*UAC
O1NTE
O*PATIENT
O1PID
R1PD1
O1PRT
O*OCCUPATIONAL_DATA_FOR_HEALTH
O1OH1
O*OH2
O*OH3
O1OH4
O*ARV
back-compatO*NTE
O*PATIENT_VISIT
O1PV1
R1PV2
O1PRT
O*INSURANCE
O*IN1
R1IN2
O1IN3
O1GT1
O1AL1
O*ORDER
R*ORC
R1PRT
O*TIMING
O*TQ1
R1TQ2
O*OBR
R1NTE
O*PRT
O*CTD
O1DG1
O*REL
O1OBSERVATION
O*OBX
R1PRT
O*NTE
O*IPC
R*DEVICE
O*DEV
R1OBX
O*Used by Events:O23OMI - Imaging order