OM2

Numeric Observation

This segment contains the attributes of observations with continuous values (including those with data types of numeric, date, or time stamp). It can be applied to observation batteries of type A and C (see OM1-18-nature of test/observation).

Figure 8-8. OM2 attributes

10
C.LenElementv2.3
1..4-NMO1-00586OM2-1Sequence Number - Test/Observation Master FileName
2..60-CEO1-00627OM2-2Units of Measure
3..10-NMO*-00628OM2-3Range of Decimal Precision
4..60-CEO1-00629OM2-4Corresponding SI Units of Measure
5..60-TXO1-00630OM2-5SI Conversion Factor
6..200-RFRO1-00631OM2-6Reference (Normal) Range - Ordinal & Continuous ObsData Type
7..200-NRO1-00632OM2-7Critical Range for Ordinal & Continuous ObsData Type
8..200-RFRO1-00633OM2-8Absolute Range for Ordinal & Continuous ObsData Type
9..200-DLTO*-00634OM2-9Delta Check CriteriaData Type
10..20-NMO1-00635OM2-10Minimum Meaningful Increments