0174

Nature of test/observation

Introduced in v2.2· user· example· Modified 2015-03-12· 5 values

Initial release in HL7 version 2.2 Version Change History: No changes Current Version as of 2.8.2 = 1

Code system of concepts specifying an identification of a test battery, an entire functional procedure or study, a single test value (observation), multiple test batteries or functional procedures as an orderable unit (profile), or a single test value (observation) calculated from other independent observations, typically used as an indicator for Master Files. Used in HL7 Version 2.x messaging in the OM1 segment.

OID & Vocabulary Information

THO Canonical URL (v2.0.0)
http://terminology.hl7.org/CodeSystem/v2-0174
Table OID
2.16.840.1.113883.12.174
Codesystem OID (v1)
2.16.840.1.113883.18.90
Value Set OID
2.16.840.1.113883.21.102
Binding
example
Expansion
All codes from codesystem
UTG Code Table
prev version
Used In Data Elements
5
A
Atomic test/observation (test code or treatment code)
THO: can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments
C
Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar--arterial ratio, cardiac output)
THO: can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment
F
Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatine clearance), usually done at different times and/or on different specimens
THO: can be associated with one or more OM4 (specimen) segments<p>See comment for value S
P
Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen
THO: can be associated with one or more OM4 (specimen) segments<p>See comment for value S
S
Superset--a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)
THO: can be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation
Definition: Superset—a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes) This set indicates that the code being described is used to order multiple service/test/observation batteries. For example, a client who routinely orders a CBC, a differential, and a thyroxine as an outpatient profile might use a single, special code to order all three test batteries, instead of having to submit three separate order codes.
5 codes