0357Has New Values3 in FHIR

Message error condition codes

Introduced in v2.3.1· hl7· universal· 13 values· 16 in FHIR

HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.

OID & Vocabulary Information

THO Canonical URL (v2.0.0)
http://terminology.hl7.org/CodeSystem/v2-0357
Table OID
2.16.840.1.113883.12.357
Codesystem OID (v1)
2.16.840.1.113883.18.217
Value Set OID
2.16.840.1.113883.21.233
Binding
universal
Expansion
All codes from codesystem
UTG Code Table
prev version
Special Values
Contains "Unknown"
Used In Data Elements

Used In Data-Type Components1

13
0
Message accepted
THO: Success. Optional, as the AA conveys success. Used for systems that must always return a status code.
100
Segment sequence error
THO: Error: The message segments were not in the proper order, or required segments are missing.
101
Required field missing
THO: Error: A required field is missing from a segment
102
Data type error
THO: Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".
103
Table value not found
THO: Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.
200
Unsupported message type
THO: Rejection: The Message Type is not supported.
201
Unsupported event code
THO: Rejection: The Event Code is not supported.
202
Unsupported processing id
THO: Rejection: The Processing ID is not supported.
203
Unsupported version id
THO: Rejection: The Version ID is not supported.
204
Unknown key identifier
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.
205
Duplicate key identifier
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.
206
Application record locked
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.
207
Application internal error
THO: This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.
Definition: An application level error has occurred and the detail for that error is identified in ERR-5.
16 codes+3 new