0357Has New Values3 in FHIR

Message error condition codes

Introduced in v2.3.1· hl7· universal· 13 values· 16 in FHIR

HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.

OID & Vocabulary Information

THO Canonical URL (v2.0.0)
http://terminology.hl7.org/CodeSystem/v2-0357
Table OID
2.16.840.1.113883.12.357
Codesystem OID (v1)
2.16.840.1.113883.18.217
Value Set OID
2.16.840.1.113883.21.233
Binding
universal
Expansion
All codes from codesystem
UTG Code Table
new cs
Special Values
Contains "Unknown"
13
0
Message accepted
THO: Success. Optional, as the AA conveys success. Used for systems that must always return a status code.
100
Segment sequence error
THO: Error: The message segments were not in the proper order, or required segments are missing.
101
Required field missing
THO: Error: A required field is missing from a segment
102
Data type error
THO: Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".
103
Table value not found
THO: Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.
200
Unsupported message type
THO: Rejection: The Message Type is not supported.
201
Unsupported event code
THO: Rejection: The Event Code is not supported.
202
Unsupported processing id
THO: Rejection: The Processing ID is not supported.
203
Unsupported version id
THO: Rejection: The Version ID is not supported.
204
Unknown key identifier
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.
205
Duplicate key identifier
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.
206
Application record locked
THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).
Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.
207
Application internal error
THO: This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.
Definition: An application level error has occurred and the detail for that error is identified in ERR-5.
16 codes+3 new