0357Has New Values3 in FHIR
Message error condition codes
Introduced in v2.3.1· hl7· universal· 13 values· 16 in FHIR
HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.
OID & Vocabulary Information
- THO Canonical URL (v2.0.0)
- http://terminology.hl7.org/CodeSystem/v2-0357
- Table OID
- 2.16.840.1.113883.12.357
- Codesystem OID (v1)
- 2.16.840.1.113883.18.217
- Value Set OID
- 2.16.840.1.113883.21.233
- Binding
- universal
- Expansion
- All codes from codesystem
- UTG Code Table
- new cs
- Special Values
- Contains "Unknown"
13
0 | Message accepted THO: Success. Optional, as the AA conveys success. Used for systems that must always return a status code. |
100 | Segment sequence error THO: Error: The message segments were not in the proper order, or required segments are missing. |
101 | Required field missing THO: Error: A required field is missing from a segment |
102 | Data type error THO: Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO". |
103 | Table value not found THO: Error: A field of data type ID or IS was compared against the corresponding table, and no match was found. |
200 | Unsupported message type THO: Rejection: The Message Type is not supported. |
201 | Unsupported event code THO: Rejection: The Event Code is not supported. |
202 | Unsupported processing id THO: Rejection: The Processing ID is not supported. |
203 | Unsupported version id THO: Rejection: The Version ID is not supported. |
204 | Unknown key identifier THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533. |
205 | Duplicate key identifier THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533. |
206 | Application record locked THO: ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Definition: Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533. |
207 | Application internal error THO: This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide. Definition: An application level error has occurred and the detail for that error is identified in ERR-5. |
16 codes+3 new