01474
Placer Supplemental Service Information
2003-08-22
Definition: This field contains supplemental service information sent from the placer system to the filler system for the universal procedure code reported in OBR-4 Universal Service ID. This field will be used to provide ordering information detail that is not available in other, specific fields in the OBR segment. Multiple supplemental service information elements may be reported. Refer to User-defined table 0411 - Supplemental service information values in Chapter 4, Section 4.5.3.47 for suggested values.
This field can be used to describe details such as whether study is to be done on the right or left, for example where the study is of the arm and the order master file does not distinguish right from left or whether the study is to be done with or without contrast (when the order master file does not make such distinctions).
Length≤250
0411Supplemental Service Information Values
6 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | O | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | O | Name of Alternate Coding System |