01475

Filler Supplemental Service Information

2007-10-26
Definition: This field contains supplemental service information sent from the filler system to the placer system for the procedure code reported in OBR-4 Universal Service ID. This field will be used to report ordering information detail that is not available in other specific fields in the OBR segment. Typically it will reflect the same information as was sent to the filler system in OBR-46-Placer supplemental service information unless the order was modified, in which case the filler system will report what was actually performed using this field. Multiple supplemental service information elements may be reported. Refer to User-Defined Table 0411 - Supplemental Service Information Values.

This field can be used to describe details such as whether study is to be done on the right or left, for example, where the study is of the arm and the order master file does not distinguish right from left, or whether the study is to be done with or without contrast (when the order master file does not make such distinctions).

Length≤705
1 values
...No suggested values<p>Individual implementations may use vocabularies such as the SNOMED DICOM Micro-glossary (SDM) or private (local) entries.Deprecated
9 components
1O-Identifier
2O-Text
3OName of Coding System
4O-Alternate Identifier
5O-Alternate Text
6OName of Alternate Coding System
7C-Coding System Version ID
8O-Alternate Coding System Version ID
9O-Original Text

Also Referenced In(1)