01898
Relationship to Subject
2011-03-06
Definition: Identification of the relationship of the consenter to the subject. Receivers are required to inspect the Coding System component of the CWE data type to accurately interpret the meaning of the code. Senders transmitting messages to Receivers on earlier version of the standard may elect to negotiate business rules to ensure that expected data is not lost. HL7 does not assign positional meaning to user-defined codes. Refer to User-Defined Table 0548 - Signatory's Relationship to Subject for suggested values.
LengthNot specified
7 values
1 | Self |
2 | Parent |
3 | Next of Kin |
4 | Durable Power of Attorney in Healthcare Affairs |
5 | Conservator |
6 | Emergent Practitioner (practitioner judging case as emergency requiring care without a consent) |
7 | Non-Emergent Practitioner (i.e. medical ethics committee) |
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |