02214
Sterilization Cycle
2011-03-06
Definition: This field contains the sterilization cycle used for sterilization of the inventory supply item. The AAMI Standard defines steam sterilization cycles - cycle names: pressure, temperature, dry time. Refer to User-defined Table 0702 - Cycle Type in SCD-28 Cycle Type.
LengthNot specified
32 values
2RS | Second Rinse |
ANR | Anesthesia/Respiratory(Special Wash cycle) |
BDP | Bedpans |
BWD | Bowie-Dick Test(A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.) |
CMW | Chemical Wash(A chemical wash cycle.) |
COD | Code |
CRT | Cart Wash |
DEC | Decontamination |
DRT | Dart(A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum.) |
DRW | Dart Warm-up Cycle(A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle.) |
EOH | EO High Temperature |
EOL | EO Low Temperature |
EXP | Express(An express cycle is similar to a flash cycle but the supply item is wrapped.) |
FLS | Flash(Used to quickly sterilize instruments that were dropped during surgery.) |
GLS | Glassware |
GNP | Gen. Purpose |
GRV | Gravity(A gravity cycle is executed at atmospheric pressure.) |
GTL | Gentle |
ISO | Isothermal |
IST | Instrument Wash |
LKT | Leak Test(A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time.) |
LQD | Liquid(A cycle specific to sterilizing liquids.) |
OPW | Optional Wash(Any Optional Wash cycle) |
PEA | Peracetic Acid(A peracetic acid cycle.) |
PLA | Plastic Goods Wash |
PRV | Prevac(A prevac cycle is vacuum assisted.) |
RNS | Rinse |
SFP | Steam Flush Pressure Pulse(An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped.) |
THR | Thermal |
TRB | Tray/Basin |
UTL | Utensil Wash |
WFP | Wrap/Steam Flush Pressure Pulse (Wrap/SFPP)(A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped.) |
22 components
| 1 | O | - | Identifier | |
| 2 | O | - | Text | |
| 3 | C | Name of Coding System | ||
| 4 | O | - | Alternate Identifier | |
| 5 | O | - | Alternate Text | |
| 6 | C | Name of Alternate Coding System | ||
| 7 | C | - | Coding System Version ID | |
| 8 | O | - | Alternate Coding System Version ID | |
| 9 | O | - | Original Text | |
| 10 | O | - | Second Alternate Identifier | |
| 11 | O | - | Second Alternate Text | |
| 12 | C | Name of Second Alternate Coding System | ||
| 13 | O | - | Second Alternate Coding System Version ID | |
| 14 | C | - | Coding System OID | |
| 15 | O | - | Value Set OID | |
| 16 | C | - | Value Set Version ID | |
| 17 | C | - | Alternate Coding System OID | |
| 18 | O | - | Alternate Value Set OID | |
| 19 | C | - | Alternate Value Set Version ID | |
| 20 | C | - | Second Alternate Coding System OID | |
| 21 | O | - | Second Alternate Value Set OID | |
| 22 | C | - | Second Alternate Value Set Version ID |