OM4

Observations that Require Specimens

The Technical Steward for the OM4 segment is Orders and Observations.

This segment applies to observations/batteries that require a specimen for their performance. When an observation or battery requires multiple specimens for their performance (e.g., creatinine clearance requires a 24-hour urine specimen and a serum specimen), multiple segments may be included, one for each specimen type.

14
C.LenElementv2.6
1-4=NMO1-00586OM4-1Sequence Number - Test/Observation Master File2
21-IDO1017000642OM4-2Derived SpecimenMin Length
31..6060=TXO1-00643OM4-3Container Description2
4-10#NMO1-00644OM4-4Container Volume2
5--CWEO1999900645OM4-5Container UnitsLength
6--CWEO1999900646OM4-6SpecimenLength
7--CWEO1037100647OM4-7AdditiveLength
8--TXO1-00648OM4-8PreparationLength
9--TXO1-00649OM4-9Special Handling RequirementsLength
10--CQO1-00650OM4-10Normal Collection VolumeLength
11--CQO1-00651OM4-11Minimum Collection VolumeLength
12--TXO1-00652OM4-12Specimen RequirementsLength
131-IDO*002700653OM4-13Specimen PrioritiesMin Length
14--CQO1-00654OM4-14Specimen Retention TimeLength
3