ORL_O22

Patient Segments Required

18 segments · 2 events

There is not supposed to be an Application Level acknowledgement to an Application Level Acknowledgement message. In Enhanced Mode, MSH-16 SHALL always be set to NE (Never).

Message Structure

18 segments
R RequiredO Optional Choice
MSH
R1
MSA
R1
ARV
O*
ERR
O*
SFT
O*
UAC
O1
NTE
O*
RESPONSE
O1
PID
R1
PRT
O*
ARV
back-compatO*
ORDER
O*
ORC
R1
PRT
O*
TIMING
O*
TQ1
R1
TQ2
O*
OBSERVATION_REQUEST
O1
OBR
R1
PRT
O*
SPECIMEN
O*
SPM
R1
SAC
O*
2 events