OM2

Numeric Observation

The Technical Steward for the OM2 segment is Orders and Observations.

This segment contains the attributes of observations with continuous values (including those with data types of numeric, date, or time stamp). It can be applied to observation batteries of type A and C (see OM1-18 - Nature of Service/Test/Observation).

10
C.LenElementv2.6
1-4=NMO1-00586OM2-1Sequence Number - Test/Observation Master File2
2--CWEO1999900627OM2-2Units of MeasureLength
3-10=NMO*-00628OM2-3Range of Decimal Precision2
4--CWEO1999900629OM2-4Corresponding SI Units of MeasureLength
5-60=TXO1-00630OM2-5SI Conversion Factor2
6--RFRO*-00631OM2-6Reference (Normal) Range for Ordinal and Continuous ObservationsLength
7--RFRO*-00632OM2-7Critical Range for Ordinal and Continuous ObservationsLength
8--RFRO1-00633OM2-8Absolute Range for Ordinal and Continuous ObservationsLength
9--DLTO*-00634OM2-9Delta Check CriteriaLength
10--NMO1-00635OM2-10Minimum Meaningful IncrementsLength
2