DICOM Module
RT DVH Module
- Attributes
- 18
- Required (Type 1 / 1C)
- 12
- Source
- PS3.3 §C.8.8.4
Overview
The provides for the inclusion of differential or cumulative dose volume histogram data. The data contained within this Module may supplement dose data in the , or it may be present in the absence of other dose data.
Attributes
Type: 1 required (non-zero), 1C required when condition met, 2 required (may be zero-length), 2C conditional, 3 optional.
| Attribute | Tag | Type |
|---|---|---|
| Referenced Structure Set Sequence | (300C,0060) | 1 |
| Include | >Include | — |
| DVH Normalization Point | (3004,0040) | 3 |
| DVH Normalization Dose Value | (3004,0042) | 3 |
| DVH Sequence | (3004,0050) | 1 |
| DVH Referenced ROI Sequence | (3004,0060) | 1 |
| Referenced ROI Number | (3006,0084) | 1 |
| DVH ROI Contribution Type | (3004,0062) | 1 |
| DVH Type | (3004,0001) | 1 |
| Dose Units | (3004,0002) | 1 |
| Dose Type | (3004,0004) | 1 |
| DVH Dose Scaling | (3004,0052) | 1 |
| DVH Volume Units | (3004,0054) | 1 |
| DVH Number of Bins | (3004,0056) | 1 |
| DVH Data | (3004,0058) | 1 |
| DVH Minimum Dose | (3004,0070) | 3 |
| DVH Maximum Dose | (3004,0072) | 3 |
| DVH Mean Dose | (3004,0074) | 3 |
Used in 1 CIOD
- RT Dose U