DICOM Module

Visual Acuity Measurements Module

Attributes
13
Required (Type 1 / 1C)
8
Source
PS3.3 §C.8.25.12

Overview

defines the Attributes used to represent the subjective measurements of a patient's visual acuity. Usually each eye is measured individually, but sometimes only one eye is measured; sometimes the visual acuity of both eyes working together is measured. The visual acuity may be measured uncorrected, or with various refractive corrections, such as best corrected distance, pinhole, habitual near, etc

Attributes

Type: 1 required (non-zero), 1C required when condition met, 2 required (may be zero-length), 2C conditional, 3 optional.

Attribute Tag Type
Viewing Distance Type (0046,0125) 1
Visual Acuity Type Code Sequence (0046,0121) 1
Include . D. >Include . D.
Background Color (0046,0092) 1
Optotype (0046,0094) 1
Optotype Detailed Definition (0046,0139) 1C
Optotype Presentation (0046,0095) 1
Visual Acuity Right Eye Sequence (0046,0122) 1C
Include >Include
Visual Acuity Left Eye Sequence (0046,0123) 1C
Include >Include
Visual Acuity Both Eyes Open Sequence (0046,0124) 3
Include >Include

Used in 1 CIOD