DICOM Attribute

Ophthalmic Anatomic Reference Point Y-Coordinate (0022,1626)

Keyword
OphthalmicAnatomicReferencePointYCoordinate
VR
FL
VM
1

Definition

The vertical offset location (row) of the anatomic reference point identified by Primary Anatomic Region Sequence (0008,2228). See for further explanation. Image relative position specified with sub-pixel resolution such that the origin at the Top Left Hand Corner (TLHC) of the TLHC pixel is 0.0\0.0, the Bottom Right Hand Corner (BRHC) of the TLHC pixel is 1.0\1.0, and the BRHC of the BRHC pixel is Columns\Rows (see ). The Value shall be within the range 0 to Rows (0028,0010). Required if Ophthalmic Anatomic Reference Point Sequence (0022,1632) is not present and Ophthalmic Volumetric Properties Flag (0022,1622) is set to YES. May be present otherwise.

From NEMA PS3.3 §C.8.17.5.

Attribute Metadata

This attribute is part of the current DICOM Standard. Its value representation is FL with multiplicity 1.

Used in 2 Modules

This attribute uses the FL Value Representation. Multiplicity 1 governs how many values may be encoded.

Integration Notes

Real-world integration guidance for engineers implementing this attribute in Mirth Connect, FHIR gateways, HL7 v2 bridges, and cloud DICOM services. Authoritative source data where available; reference examples and operational notes where they add value.

FHIR Mapping

No direct FHIR ImagingStudy mapping published for this attribute. Some tags map indirectly via the Patient, Endpoint, or ImagingSelection resources — Phase 2b will expand coverage to those.

HL7 v2 Equivalent

No standard HL7 v2 equivalent published for this attribute. Imaging-only attributes (Image Pixel data, technical acquisition parameters, modality-specific values) typically have no HL7 v2 carrier.

Cloud DICOM Support

AWS HealthImaging, Azure DICOM, and GCP Healthcare DICOM coverage rolls out by attribute. The QIDO-RS matching keys + Patient/Study/Series core (~50 attributes) are documented; lower-traffic attributes will be added as Saga teams encounter them in production.

Real-World Sample Values

No representative sample value available — this attribute isn't present in the de-identified pydicom fixture set. Add a fixture covering this attribute to expand coverage.

Mirth Connect Example

JavaScript transformer snippets for the most-queried tags will be added as coverage expands.

Common Operational Errors

Operational error patterns for the most-queried tags will be added as coverage expands.

DICOM Integration Services

Saga IT builds production DICOM integrations across Mirth Connect, FHIR gateways, and cloud imaging platforms. If you're working with OphthalmicAnatomicReferencePointYCoordinate or the broader (0022,1626) context: