DICOM Attribute

RT ROI Interpreted Type (3006,00A4)

Keyword
RTROIInterpretedType
VR
CS
VM
1

Definition

Type of ROI. See . Defined Terms: EXTERNAL external patient contour PTV Planning Target Volume (as defined in ) CTV Clinical Target Volume (as defined in ) GTV Gross Tumor Volume (as defined in ) TREATED_VOLUME Treated Volume (as defined in ) IRRAD_VOLUME Irradiated Volume (as defined in ) OAR Organ at Risk (as defined in ) BOLUS patient bolus to be used for external beam therapy AVOIDANCE region in which dose is to be minimized ORGAN patient organ MARKER patient marker or marker on a localizer REGISTRATION registration ROI ISOCENTER treatment isocenter to be used for external beam therapy CONTRAST_AGENT volume into which a contrast agent has been injected CAVITY patient anatomical cavity BRACHY_CHANNEL brachytherapy channel BRACHY_ACCESSORY brachytherapy accessory device BRACHY_SRC_APP brachytherapy source applicator BRACHY_CHNL_SHLD brachytherapy channel shield SUPPORT external patient support device FIXATION external patient fixation or immobilization device DOSE_REGION ROI to be used as a dose reference CONTROL ROI to be used in control of dose optimization and calculation DOSE_MEASUREMENT ROI representing a dose measurement device, such as a chamber or TLD DEVICE device not addressed by another Defined Term

From NEMA PS3.3 §C.8.8.8.

Attribute Metadata

This attribute is part of the current DICOM Standard. Its value representation is CS with multiplicity 1.

Used in 1 Module

This attribute uses the CS Value Representation. Multiplicity 1 governs how many values may be encoded.

Integration Notes

Real-world integration guidance for engineers implementing this attribute in Mirth Connect, FHIR gateways, HL7 v2 bridges, and cloud DICOM services. Authoritative source data where available; reference examples and operational notes where they add value.

FHIR Mapping

No direct FHIR ImagingStudy mapping published for this attribute. Some tags map indirectly via the Patient, Endpoint, or ImagingSelection resources — Phase 2b will expand coverage to those.

HL7 v2 Equivalent

No standard HL7 v2 equivalent published for this attribute. Imaging-only attributes (Image Pixel data, technical acquisition parameters, modality-specific values) typically have no HL7 v2 carrier.

Cloud DICOM Support

AWS HealthImaging, Azure DICOM, and GCP Healthcare DICOM coverage rolls out by attribute. The QIDO-RS matching keys + Patient/Study/Series core (~50 attributes) are documented; lower-traffic attributes will be added as Saga teams encounter them in production.

Real-World Sample Values

No representative sample value available — this attribute isn't present in the de-identified pydicom fixture set. Add a fixture covering this attribute to expand coverage.

Mirth Connect Example

JavaScript transformer snippets for the most-queried tags will be added as coverage expands.

Common Operational Errors

Operational error patterns for the most-queried tags will be added as coverage expands.

DICOM Integration Services

Saga IT builds production DICOM integrations across Mirth Connect, FHIR gateways, and cloud imaging platforms. If you're working with RTROIInterpretedType or the broader (3006,00A4) context: